furaat earth private limited

Service & Maintenance

Service & Maintenance

Furaat Service and Maintenance ensure optimal performance, efficiency, and longevity of rainwater harvesting systems

Key Benefits
  • Extended system life and reliability
  • Consistent filtration and recharge efficiency
  • Reduced maintenance issues and downtime
  • Sustainable and hassle-free system operation
25+
Years of Experience
1000+

Projects Executed

1000

Crores Litres Conserved

100+

Esteem Clients

Key Services
Recharge Well Icon
Annual Maintenance Contracts (AMC)

Scheduled servicing for continuous system performance

Recharge Well Icon
Regular Inspection

Complete system checks including storm water drains, filters, recharge wells and tanks

Recharge Well Icon
Cleaning & Debris Removal

Cleaning of primary and secondary modules to prevent clogging

Recharge Well Icon
System Integrity Check

Inspection of pipes, joints, and fittings to avoid leaks or damage

Recharge Well Icon
Performance Evaluation

Monitoring filtration efficiency and water percolation

Recharge Well Icon
Documentation & Reporting

Detailed reports on system condition and maintenance activities

Recharge Well Icon
Repairs

Response for unexpected breakdowns or issues

Recharge Well Icon
Client Training & Support

Guidance on best practices for usage and upkeep

Furaat Maintenance

Precast Modular Step Well SFM 2350/3475

Maintenance SFM

01. Open lid carefully after clearing visible deposits on the top

Maintenance SFM

02. Remove gravels from the top chamber on a tarpaulin

Maintenance SFM

03. Clean gravel thoroughly with pressurized water

Maintenance SFM

04. Lift intermediate lid with care to access sand bed

Maintenance SFM

05. Remove top 5 cm layer of sand, wash it, and put it back, do not disturb the rest

Maintenance SFM

06. In case of heavy sedimentation remove entire sand from the top module on a tarpaulin and wash it thoroughly with clean water

Maintenance SFM

07. Clean stainless steel screen using a brush, ensure slots are clean and clear

Maintenance SFM

08. Wash screen and the inner walls with clean water, allow it to dry

Maintenance SFM

09. Before putting washed sand back in the bottom module ensure corners are free from deposits or unwanted growth. It is important that level of sand always stays at least 5 cm above the top level of stainless screen.

Maintenance SFM

10. Place spacers for intermediate lid

Maintenance SFM

11. Place inter-mediate lid back on the spacers

Maintenance SFM

12. Fill washed gravels back in top module

Maintenance SFM

13. Close top Lid carefully

Maintenance SFM

14. Always keep harvesting unit and its surrounding clean

Furaat Maintenance

Precast Modular Step Well HFM 2350/3475

Maintenance SFM

01. Open lid carefully after clearing visible deposits on the top

Maintenance SFM

02. Rinse gravels thoroughly with water and wait for a while

Maintenance SFM

03. Use pressurized water from inside out to back flush all entry points

Maintenance SFM

04. In case of heavy sedimentation remove entire gravel from the top module on a tarpaulin and wash it thoroughly with clean water

Maintenance SFM

05. Remove the spine assembly before opening intermediate lid

Maintenance SFM

06. Lift intermediate lid with care to access sediment module

Maintenance SFM

07. Scrape all visible sediments from bottom module

Maintenance SFM

08. Wash inner walls with clean water, allow it to dry

Maintenance SFM

09. Close the intermediate lid carefully Put spine assembly back in place

Maintenance SFM

10. Before putting washed gravel back in the bottom module. ensure comers are free from deposits or unwanted growth. Level of graveis must stay at least 5 cm above the top level of 64 inlets

Maintenance SFM

11. Clean all 64 inlets with brush and water, ensure all are clear and clog free

Maintenance SFM

12. Close top lid carefully

Maintenance SFM

13. Brush clean top and outer surfaces

Maintenance SFM

14. Visual Inspection at regular intervals and Protective Coating will add life to Harvesting System

Important : Furaat Rainwater Harvesting Systems Are Meant Only For Rainwater, Any Discharge Fed To These System Will Not Only Reduce Its Performance, But Also Damage Underground Aquifers Permanently, It Is A Punishable Offence